Home New Customer? Create Account
Member Login:

Automated Nucleic Acid Extraction

IMC-NC15PLUS - Miracle-AutoXT Automated Nucleic Acid Extraction System

PRICE


Call for Price

Obtain high yield, high purity DNA/RNA and improve efficiency with magnetic bead-based automated extraction!

Miracle-AutoXT is an FDA-registered system for fast, efficient nucleic acid extraction. The system provides high yield, high purity DNA/RNA, with up to 32 samples processed simultaneously. Extraction is completed in as little as 20 minutes.

The Miracle-AutoXT system functions by bead based-extraction. The magnetic bed moves during operation and automatically extracts nucleic acids, minimizing contamination and errors. Reactions are further optimized with heating and high speed mixing functions. With a self-check mode and simple updates, this system is easy to operate and maintain.

High Speed Extraction

  • Extractions do not require time-consuming pre- and post-processing, as lysis, washing, and elution occur at the same time
  • Up to 32 samples can be processed simultaneously (32 in well plates and 16 in individual plates)
  • High-speed vibrator function (900 rpm)

Durable Structure

  • Durability of inner structure allows consistent results to be achieved
  • Low noise and vibration during operation
  • Compact size (340 x 420 x 345mm)

Easy Operation and Maintenance

  • Simple program with easy controls and updates
  • Test Mode operation enables self-check (2 minute process)
  • Updates are easily performed with a USB connection (5 minutes process) 
  • Hidden operation functions (Calibration Mode and Temperature Setting Mode)

Built-In Heating Block

  • Heating function optimizes reactions for increased yield and purity
  • Consistent results are achieved regardless of environmental changes
  • Reduced EtOH contamination in elution stage

Minimal Contamination

  • UV lamp prevents cross-contamination
  • Automation minimizes errors between users

Compatible Extraction Kits

 

 

Specifications

Parameter Specification
Extraction Method Bead-based DNA/RNA extraction
Number of Samples Up to 32 samples
Processing Time 20-45 minutes
Touch Monitor 7 inches
Convenience Functions  Self test, USB update
Input Power Universal Supply 100~240VAC, 50-60Hz, 1.5A
Output Power +24VDC +3% (150W maximum)
Power Supply UL/CSA/CE approved universal power supply with IEC connection
Dimensions 340 x 420 x 345mm (13.88 x 16.53 x 13.58 inches)
Weight 24kg (52.9 lbs)
Operating Temperature 10-40°C (50-104°F)
Relative Humidity 30-85% RH non-condensing
UV Lamp Lifetime 4800 hours

 

Literature